Air Showers offer an effective way to reduce contaminants carried by individuals entering or leaving a controlled area. The Air Shower can solve many of your decontamination problems. Air Shower tunnels are protected passageways that allow large volumes of personnel to pass into controlled areas. Air Showers and Tunnels supply concentrated CLASS 100 sterile air flows to lift off contamination while an individual stands in, or walks through, a specially constructed air chamber. Pressurized air streams from nozzles at a velocity between 6,000 and 8,000 feet per minute, which ensures efficient scrubbing action necessary to remove particulate matter. Contaminated air is directed downward through grilles and hollow walls of the Air Shower to the filter. 99.97% of all particles as small as .3 microns are removed. Halco Air Showers and Air Shower Tunnels are economical to operate, and require a minimum of maintenance.

Download Brochure



FEATURES:

SOLID STATE ELECTRICAL MICROPROCESSOR SYSTEM CONTROL PANEL INCLUDES:

  • Light Switch, audible alarm and alarm reset.
  • 4 Line 64 character alpha/numeric LCD display which monitors system function during normal operation and displays menu functions for service and system changes.
  • 16 Key membrane keypad for system operation.
  • 4 Number code to turn control on and off
  • 4 Number code to get into systems setup
  • Microprocessor programming capabilities:
  • Program time of day
  • Program day of the week
  • Program cycle time
  • Program delay unlock time
  • Designate entry and exit doors
  • Program new 4 digit code enter system
  • Program time lock feature
  • Initiate security locking feature with 4 digit code
  • Initiate single direction access feature
  • Interlocking doors (standard), which release automatically with power failure.
  • Fluorescent lighting (standard) is contained in the ceiling for less turbulence.
  • HEPA Ceiling (optional) for constant laminar flow for added protection.
  • Ionized Grid (optional) to eliminate static electricity when required.
  • Microprocessor diagnostic capabilities:
  • Air shower disabling feature
  • Blower operations check
  • Door switch operations check
  • Door lock operations check
  • Presence sensor/mat switch check
  • Record blower run hours
  • Record air shower cycles



 

Optional Equipment  

  • Safety Plate Glass Doors
  • Magnahelic Gauge HEPA
  • Magnahelic Gauge Prefilter
  • Photohelic Gauge with Alarms
  • Aluminum Grated Floor with Clean Out Pan
  • Sprinkler Head
  • Laminar Ceiling Blower
  • Auto Bi-Part Doors
  • Proximity Sensor
  • TEFC or Special Frame Motors
  • Models:
  • L - 90 Degrees "L" Shaped
  • U - "U" Shaped
  • 3D - Three Door
  • KD - Knock Down Assembly (Standard)
  • SM - Side Mount HEPA, Motor Blower
  • HFC - HEPA Filter Ceiling
  • IG - Ionized Grid
  • NF - No Floor
  • EXP - Explosion Proof
  • RFR - Raised Floor Return
  • Halco will custom build to exact specifications.
  •  


    AIR SHOWER TUNNEL

    ASFP_1.gif

    AIR SHOWER MODELS
    Frequently Asked Questions
     

    HALCO PERSONNEL AIR SHOWERS

    Air Shower Tunnels

    Model #

    337

    347357367447457 46755756766777731273157

    (A) Base Sec. HT.*

    90909090909090909090909090

    (B) Width

    52525252585858646470845252

    (C) Length

    4456607256607260727284144180

    (D) Blower Box HT.

    26263030303030303030303030

    (E) Door Width

    30303030363636424248
    3030

    (F) Width—ID

    35.535.535.535.541.541.541.547.547.553.5
    35.535.5

    (G) Length—ID Clear

    35475163475163516363
    135171

    No. Nozzles

    20203236323236323640
    6096

    Qty. Blowers

    1111111111
    33

    CFM/Blower @ 2” WG

    1010101018201820182018201820182018201820
    30305460

    RPM

    3600360036003600360036003600360036003600
    36003600

    Wheel Dia.

    12.512.513.513.513.513.513.513.513.513.5
    12.513.5

    3 Door Available

    NoNoYesYesNoYesYesYesYesYes
    YesYes

    Shipping Wt.

    1600180019002100180020002200200022002400
    53005700

    Filter size—11½ deep x

    18x2418x2424x2424x2424x2424x2424x2424x2424x2424x24
    3-18x243-24x24

    H.P.

    2255555555
    3-2HP3-5HP

    *HFC Model—for HEPA Filter Ceiling Model add 6” to base section height.

    *SPECIAL SIZES ARE ALSO AVAILABLE UPON REQUEST.


    Air Shower Parts

    DK12 - Air Shower Presence Sensor
    Availability:7-10 Days Contact Us
    Price:$700.00
    Shipping:Included
    MCPV3 2.65 - Air Shower Microprocessor Control
    Availability:7-10 Days Contact Us
    Price:$2400.00
    Shipping:Included
    Personal Information